Dental Plaque Analyzer
Upload a photo of the teeth to prepare it for analysis
About the platform
A research platform for calculating the dental plaque percentage from tooth photographs, designed for dental researchers. The platform detects the teeth automatically, separates the stained plaque from the tooth surface, and then calculates the percentage, with tools for reviewing and manually adjusting the selection and exporting the results.
- Your images never leave your device: the entire analysis runs inside the browser, and no image is uploaded to any server.
- Two supported dyes: fluorescent dye under ultraviolet light, and blue or pink disclosing dye.
- Documentable results: a colored image with the result, files that open in Excel, and a log of patient results using codes instead of names.
Disclaimer: this is a research tool, not a medical device, and it must not be used for diagnosis.
Dye type
Healthy teeth: No plaque is counted. The platform detects the teeth automatically and reports their area in pixels (all pixels inside the teeth region). Review the region boundaries, and enable the "Separate the upper and lower jaws" option if you need a separate result for each jaw.
Upload image
Drag and drop the image here
or
Allowed: JPG or PNG images only, up to 20 MB, with maximum dimensions of 6000×6000 pixels.
Checking the image…
Compare two images
Enter a label for each image (such as the name of the medication or treatment, without the patient's name), then upload both images. The platform detects the teeth in each image automatically and analyzes both images with exactly the same settings, then shows the difference between them. For an accurate comparison, use the same camera, the same lighting, and approximately the same distance.
The settings have changed since the last comparison. Click "Compare" to update the result.
Image under analysis
Click and drag the pointer over the gums. The pink area is never counted, even if it is green.
The overlay is currently hidden to keep the image clear while drawing, and the percentage is still being calculated. Enable "Show overlay on the image" to display it.
To zoom: click the "Zoom in +" button, or hold Ctrl while turning the mouse wheel. To move the zoomed image: drag it with the mouse. Zoom in before drawing so that the points are placed precisely.
The image was redrawn on a canvas inside the browser, so its hidden metadata was removed (such as EXIF data and the GPSlocation). The analysis runs on this copy only.
Analysis
Plaque percentage
—
Color thresholds (move them and watch the overlay on the image)
Explanation of thresholds and automatic suggestion
Suggest thresholds automatically: the thresholds are determined automatically by color thresholding to isolate the required pixels, after the image has been converted to the color space HSB.
The hue value (H) ranges from 0 to 179, and the saturation (S) and brightness (V) values range from 0 to 255. If the minimum hue value is greater than the maximum value, the range wraps around red (for example, from 170 to 10). If the tooth range overlaps the plaque range, the pixel is counted as plaque. The default values are intended for testing only and must be calibrated according to the research images.
- Light shading: tooth pixelsLight shading: counted teeth area
- Red: plaque pixels
- Uncolored: excluded (gums, lips, tongue, background)
Percentage = plaque pixels ÷ (tooth pixels + plaque pixels) × 100
The platform places 4 curved white lines at the canine boundaries, running through the natural gap between the canine and the premolar, and the teeth behind them are dimmed and not counted. The blue line is exactly the border of the area that is counted. Review them in every image: drag the circle or the small points along a line to adjust its shape, and drag the orange diamond at the end of the line to move the whole line to another gap, where it snaps automatically.
An orange line with five circular points appears on the image: drag each point up or down until the line lies between the upper and lower teeth. Everything above the line represents the upper jaw, and everything below it represents the lower jaw. The platform places the line automatically along the shadow between the jaws, and you should review it.
Results log
After any analysis or comparison, enter the patient code and click "Add". The results are collected in a single table, ready to download and save in Excel format for statistical analysis.
The log is empty.
The log is saved in your own browser and is not uploaded anywhere. Clearing the browser data deletes the log (make sure to download the log and keep the file).
Analysis engine: loading…